When setting up a brewery, choosing the right glycol chiller is essential for maintaining stable fermentation temperatures.
But how much cooling capacity do you actually need?
If the glycol chiller is used only for fermentation tank cooling, rather than rapid wort cooling, the required capacity is usually much lower.
Let’s take a practical example.
1. Calculate the Fermentation Cooling Load
Suppose a brewery has 8 fermentation tanks, each with a 1,000L working volume.
During fermentation, yeast generates heat as it converts sugars into alcohol and COā. The glycol cooling system removes this heat to maintain the desired fermentation temperature.
For a preliminary estimate, let’s assume a peak cooling load of 0.3 kW per 1,000L fermenter.
The calculation is:
- Number of fermenters: 8
- Cooling load per fermenter: 0.3 kW
- Total cooling load: 8 Ć 0.3 = 2.4 kW
- With a 25% safety margin: 2.4 Ć 1.25 = 3.0 kW
Therefore, approximately 3.0 kW of cooling capacity is required under these assumed conditions.
2. Recommended Glycol Chiller: 3HP
<escape>Tiantai’s 3HP air-cooled glycol water chiller (Model: ICA-3M) provides a cooling capacity of 4,500W (4.5 kW), with a glycol water outlet temperature of -5°C at an ambient temperature of 35°C.</escape>
Key specifications:
- Model: ICA-3M
- Cooling capacity: 4,500W
- Installed power: 3.3 kW
- Power supply: 380V / 3-phase / 50Hz
- Glycol outlet temperature: -5°C
- Refrigerant: R407C
- Compressor: Copeland and other leading brands, depending on configuration
- Evaporator: 304 stainless steel shell with corrosion-resistant copper tube
- Intelligent temperature control and multiple safety protections
The 3HP glycol chiller can cool 7-8 1000L fermenters at the same time.
This configuration is suitable for breweries where the glycol chiller is dedicated to fermentation temperature control and does not handle the initial wort cooling process.

3. Need Help Selecting a Glycol Chiller?
The actual cooling demand depends on the number of tanks, fermentation temperature, brewing schedule, ambient conditions, and insulation performance.
At Tiantai, we can help calculate the cooling load and recommend a suitable glycol chiller for your brewery.
Share your tank quantity, working volume, and fermentation temperature with us, and let’s find the right cooling solution for your project!
š¤ Cassie
š§ [email protected]