How to Choose a Glycol Chiller for Fermentation Tanks?

When setting up a brewery, choosing the right glycol chiller is essential for maintaining stable fermentation temperatures.

But how much cooling capacity do you actually need?

If the glycol chiller is used only for fermentation tank cooling, rather than rapid wort cooling, the required capacity is usually much lower.

Let’s take a practical example.

1. Calculate the Fermentation Cooling Load

Suppose a brewery has 8 fermentation tanks, each with a 1,000L working volume.

During fermentation, yeast generates heat as it converts sugars into alcohol and COā‚‚. The glycol cooling system removes this heat to maintain the desired fermentation temperature.

For a preliminary estimate, let’s assume a peak cooling load of 0.3 kW per 1,000L fermenter.

The calculation is:

  • Number of fermenters: 8
  • Cooling load per fermenter: 0.3 kW
  • Total cooling load: 8 Ɨ 0.3 = 2.4 kW
  • With a 25% safety margin: 2.4 Ɨ 1.25 = 3.0 kW

Therefore, approximately 3.0 kW of cooling capacity is required under these assumed conditions.

2. Recommended Glycol Chiller: 3HP

<escape>Tiantai’s 3HP air-cooled glycol water chiller (Model: ICA-3M) provides a cooling capacity of 4,500W (4.5 kW), with a glycol water outlet temperature of -5°C at an ambient temperature of 35°C.</escape>

Key specifications:

  • Model: ICA-3M
  • Cooling capacity: 4,500W
  • Installed power: 3.3 kW
  • Power supply: 380V / 3-phase / 50Hz
  • Glycol outlet temperature: -5°C
  • Refrigerant: R407C
  • Compressor: Copeland and other leading brands, depending on configuration
  • Evaporator: 304 stainless steel shell with corrosion-resistant copper tube
  • Intelligent temperature control and multiple safety protections

The 3HP glycol chiller can cool 7-8 1000L fermenters at the same time.

This configuration is suitable for breweries where the glycol chiller is dedicated to fermentation temperature control and does not handle the initial wort cooling process.

chiller

3. Need Help Selecting a Glycol Chiller?

The actual cooling demand depends on the number of tanks, fermentation temperature, brewing schedule, ambient conditions, and insulation performance.

At Tiantai, we can help calculate the cooling load and recommend a suitable glycol chiller for your brewery.

Share your tank quantity, working volume, and fermentation temperature with us, and let’s find the right cooling solution for your project!

 

šŸ‘¤ Cassie
šŸ“§ [email protected]

Get A Quote

If you have other questions, please do not hesitate to leave your email address below, we are pretty happy to contact you soonest!

Contact Form Demo

FAQ

Do you offer installation and training services?

Yes, we provide professional installation guidance and on-site training. Our team of nearly 20 experienced installation engineers and brewmasters will ensure your equipment is correctly installed and operating smoothly, maximizing your success from start-up.

Certainly. Please share your floor plan with us, and our technical team will be glad to design a tailored equipment layout based on your specific requirements and space constraints.
We offer the following warranty coverage: – 5 years on the tank body under normal operating conditions. – 1 year on all accessories and auxiliary facilities. – 3 months on wearing parts and sensitive components, such as pump seals, gaskets, and sensors.